AE-2 RESIDENTIAL TELEPHONE ENTRY
AE-1 Residential Phone Entry  $
1499.00 Call for special pricing

access control
Download brochure

The Linear Telephone Entry combines telephone entry with full-featured access control, including keyless entry and panic functions. It is extremely easy to operate, making it ideal for a wide range of applications, including apartments, condominiums, dormitories, office buildings, and gated communities. It offers security, convenience, and handicapped access. As a telephone entry system, it provides full duplex telephone communications through hands-free operation, and controls four openings via touch-tone telephone. It is supplied in a rugged, stainless steel, surface mount housing that will withstand years in the toughest environments. Numerous programming options allow the installer to customize Telephone Entry for virtually any application. System choices include selection of a one-to-four digit directory code, 40 different display messages, talk time duration, and extended talk time for select individuals.
Remarkable ease of operation is made possible by a highly visible keypad and large display, which presents visitors with a scrolling directory of up to 3,500 occupants (residents or employees) by name and code. When a code is entered on the keypad, a two-way voice link is established so the occupant can identify the visitor and grant access. Occupants gain entry using a special transmitter by keyless entry. Beyond telephone entry, the system can be adapted for use with other forms of access control, as well as with existing access control systems. Adding transmitters is easy because the system includes a built-in radio receiver. Transmitters can be used for the convenience of keyless entry, but also to equip the system with “panic button” capability for duress situations, ideal for sites with detached parking areas.
GENERAL SPECIFICATIONS:
  • Communications: Full duplex, hands-free operation
  • Programmable Features: 1- to 4-digit directory code; 40 display messages; talk time duration; extended talk time for select users
    OUTPUTS:
  • Relay: Four form "C" relays, rated at 3 amps with programmable output duration; all four can be configured for open/close; A and B can be supervised for status; C and D can be configured for control; all relay contacts have RFI, ARC, and lightning suppression
  • Wiegand: Wiegand compatible signals for adding RF capability to other access control systems; 26 , 30 , and 31 bit formats are supported
  • RS232: One port for connection to a local computer printer, or CRT; all communications are at 9600 baud
    DISPLAYS:
  • Front Panel: Vacuum fluorescent, two lines by 20 characters
  • Internal Controller: Two lines by 24-character backlit display for local programming and transaction monitoring
  • LED Indicators: Internal controller has front panel indicators for all input and output activity for on-site troubleshooting
    INPUTS:
  • RF: 318 MHz superheterodyne receiver with -90 dBm sensitivity; built-in 20 dBm adjustable attenuator for fine tuning radio performance
  • Keypad/Reader: Two sets of inputs for connecting remote keypads, card reader interfaces, or remote receivers
  • Open Request: Contact closure to ground activates channel A or B relays
  • Programming: Internal keypad for local programming
  • Access Buttons: One button for each of the four relays

    FEATURES:

    • Ideal for apartments, condos, gated communities, dormitories, offices and other commercial sites.
    • Extensive capacity - up to 3,500 users.
    • Controls up to four portals via touch-tone telephone and keypad entry.
    • RS485 capability for networking up to 32 doors.
    • Full duplex telephone communications.
    • Built-in radio for keyless entry - wireless activation from up to 250 feet away field.
    • Programmable directory, talk time, and display message.
    • Selectable extended talk time.
    • Accepts inputs from remote keypads, Wiegand cards, and proximity devices.
    • Programming via built-in keypad or PC software.
    • Large,vacuum fluorescent display, 2 lines by 20 characters.
    • Optional sunlight visor and stainless steel post mounting plate.
    • Can be networked - up to 64 units.
    • Windows based software for installation management.
OPERATING TEMPERATURE:
  • Electronics: -22° to +149° F (-30° to +65° C)
  • LCD Display: 0° to 104° F (-18° to +40° C)
  • MEMORY: All data memory is non-volatile EEPROM with data retention in excess of 10 years; modular design permits field upgrading and easy transfer to another controller; memory modules available in the following capacities: 64K capacity, medium memory 128K capacity, large memory 256K capacity, extra-large memory
  • CLOCK/CALENDAR: Built-in-24-hour clock/calendar with battery backup and daylight savings adjustment
  • CONNECTIONS: All wiring connections to the internal controller are plug-on, screw terminal blocks
  • ENCLOSURE: Rugged stainless steel, surface mounting
  • STANDARD EQUIPMENT: Four portal Telephone Entry System; contains system controller with built-in radio receiver; RS232 port, and Wiegand outputs; accepts transmitters, keypads, and antenna; includes two line by 16 character LCD display
  • DIMENSIONS: 15 in W x 11.5 in H x 5.25 in D (381 x 292 133 mm
 
Gate operator installations should be completed by a qualified installer only. Intercom-Access  assumes no liability if product is installed incorrectly. Please see owners / installation instructions for complete details.
For Sales Information
mail@intercom-access.com
Partner Websites for more products:
Liftmaster automatic Gates  Electric gate openers   Guard Tour products Elite electric Gates
Hydraulic Gate Openers  Barrier Gates  Telephone Entry/ Intercoms Sentex Parts
Gate Parts  FAAC Parts  Electric gates  Gate Openers
 

Access Control , Telephone Entry, Entry Access, entry system, telephone entry systems, entry systems, telephone entry system, KeriSystems

 
      TELEPHONE: (775) 588-1475       FAX: 775-588-1473    
     BUSINESS HOURS:   7:30 am to 4:00 pm PST

 
Terms /Conditions/Guarantee & Return Policy

Copyright © 2009 Intercom-access