PERS-2400A PERSONAL EMERGENCY REPORTING CONSOLE
|

|
Linear has
built a lot of capability into the PERS-2400A, a 24-hour personal
emergency reporting system. It is a flexible emergency, fire, and
inactivity reporting package, but can also be custom programmed by the
installer to work with and report several other functions. With 16
reporting zones, it can work with and report individual emergency alarms
for up to 16 users. It can be used to provide delayed alarm functions
and can be configured to act as a speakerphone.
Brochure
Manual |
Features:
- Two-way voice capability (with
optional VB4 voice board).
- Suitable for temporary or permanent
installations.
- Braille characters for emergency,
home, and clear functions.
- Speaker phone capability (with
optional VB4 voice board).
- Delayed, silent alarm feature.
- Selectable inactivity reporting: 8,
12, or 24 hours.
- Selectable two-way voice activation
(with optional VB4 voice board).
- In and out telephone jacks.
- 32 hour battery back-up.
- Distinct alarm tones provided for
emergency and fire alarm conditions.
- Power on/off switch.
- Capacity for up to 16 DX/DXS
transmitters.
- Point ID communicator reporting.
- Programmable with Windows-based
RA-2400 Software.
- Installs in minutes.
- UL listed per standard 1637.
Click Here for Pricing
|
GENERAL SPECIFICATIONS:
Electrical:
Primary Operating Voltage: 120 VAC, 60 Hz
Transformer: UL listed, Class II, plug-in, 16 VAC, 1.25 A (supplied)
Back-Up Battery: Recommended battery is 12V, 1.2 amp-hour; Linear part
number 100104 (order separately)
Standby Current Drain: 80 mA without VB-4, 110 mA with VB-4
Alarm Current: 130 mA
Backup Operation: 32 hours minimum with VB-4 voice board installed in
the unit
Radio Receiver:
Type: Diversity, dual superheterodyne
Operating Frequency: 315 MHz
Transmitter Capacity: 16 DX or DXS devices
RF Programming Method: Linear quick-learn
Compatible RF Formats: Linear DX, DXS
Console:
Radio Zones: 16 supervised
Relay Output: Form "A" normally open common alarm contact
Contact Rating: 1 amp @ 12 VDC
Control Switches: Emergency with Braille, Home with Braille
"H", Clear with Braille "C"
Indicators: LED type labeled Power On, Sending, Trouble, and Home
Inputs: In and out telephone jacks; connection terminals for PD-2 dialer
Programming Method: Via RA-2400 remote access software
Output Tones: Distinct alarm tones provided for emergency and fire alarm
conditions; provisions for timer reset tone also incorporated into
system
Silent Alarm Feature: Software programmable per channel
Pulse/Tone Dialing: Software or console programmable
Audible Output: Integral siren
Operating Temperature: 32° to 120° F (0° to 49° C)
Regulatory: FCC, DOC, UL 1637
Communicator:
Dialing: DTMF or pulse dialing; pulse speed (10 PPS, 60% break, 40%
make)
Ringer Equivalence: 0.4 B
Reporting Formats: 4 x 2 or Ademco Contact ID
Telephone Numbers: Primary, secondary, and supervisory
Reports: Full transmitter reports, console reports, general system
reports, and inactivity
Physical Console:
Dimensions: 8.75 in L x 7.50 in W x 3.00 in H (222 x 190 x 76 mm)