TECHNICAL SPECIFICATION
Power Input: 12VAC/DC 40VA UL Listed Transformer (12VAC is supplied by Pach & Company). Output voltage must be reading 13.5 - 14.5 V if 12VDC power supply is used.
Current Consumption: 350mA Idle, 475mA operation.
Emergency Battery: 12VDC, 4Ahr rechargeable (customer supplied).
Communication: RS-485 (maximum distance not to exceed 4000 ft, daisy chain connection)
Operating Environment: 0°F to +140°F. Relative Humidity 0% to 95%.
Relay Output: From C Dry Contact 120VAC 10A/ 24VDC 10 A/ 250VAC 7A with 5 seconds output duration.
INSTALLATION REQUIREMENT:
POWER INPUT: 18 gauge-2conductors stranded wire.
RS-485: 18 gauge-2conductors shielded stranded wire (maximum distance from the main lobby panel to the last SCR9 not to exceed 4000 feet, daisy chain connection from one SCR9 to another SCR9 and install 120 ohms resistor on the last SCR9, ground one end of the shielded to the earth ground).
GROUNDING: 16 gauge solid wire to ground the enclosure to the earth ground.
DOOR STRIKE/GATE OPERATOR: 16-18 gauge-2conductors stranded wire.
WARNING:
All wires must be in separate jacket for each connection. Using wires in the same jacket may create problem to the system performance.
Do not use the system's power transformer to power another devices, unless specified by the manufacturer.
Each system must be powered using separate power transformer, unless specified by the manufacturer.
Mounting: Surface, Indoor or outdoor (can be mounted on APM1, APM2, APM3, APM4 and APM5).
Construction: 16 Gauge Cold Rolled Steel with Brushed Stainless Steel Faceplate.
Dimension: 6 3/4” (H) x 5 3/4 “ (W), Depth 3 1/2” (top) to 2 1/2”(bottom).
Shipping Weight: 4 Lbs.